To introduce myself for an available position in your organization. My diversified and in depth professional work experience at SEPCO-III Haveli Bahadur Shah Powerplant (1230MW) District Jhang Punjab.(as Control room Operator) coupled with a record of outstanding performance at academic levels (as detailed in my resume) has enabled me to present myself as a potential candidate for a suitable position in an organization that can fulfill my need for incessant professional development and provide an opportunity for career growth.
10 Ton Boiler are Used to Steam at Drying Process at Towel Industry. 01 MW Engine Cummins Company Used at Backup Power Supply for Industry Machineray. Normally K-Electric Power Supply are Used. 02 Other Engine of Genbechar GE Company 350 KW are Used to Backup of PowerSupply. And also Handle the Electrical Operation Team, Manage Shifts to Handle the Plant Normal Condition.
Responds safety in an manner during process upset conditions specially in trip & blackout condition of the plant and responsible to ensuring actions are carried out in accordance with agreed black out Procedure.
Diagnose process problems brought in the notice of Shift engineer mention in log book and prepare detail work requests for rectification through Maximo work request system.
Start-up & Shutdown of 02 Frame 9HA Gas Turbine 430 MW With Dry Low Nox 2.6+ Combustion System & Generator Having Hydrogen Cooling System.
Startup Shutdown of 02 Alstom High Pressure HRSG (Pressure=178bar Temprature= 585c Flow= 500 Ton/hr).
Startup Shutdown of Alstom Steam Turbine 415 MW Having (HP= 28 stages, IP=17 Stages, LP= 10 Stages) & Generator Having Hydrogen Cooling System.
Switching Of 11KV Breakers For Plant Supply.
Operation Of Cooling Water Pumps Having 3.5 MW Power & Cooling Tower System.
Operation Of Water Treatment Plant Such as Clarifier, RO, Ion Exchange System.
Responds safety in an manner during process upset conditions specially in trip & blackout condition of the plant and responsible to ensuring actions are carried out in accordance with agreed black out Procedure.
Diagnose process problems brought in the notice of Shift engineer mention in log book and prepare detail work requests for rectification through Maximo work request system.
My Job Responsibilities is Startup / Shutdown of Following
GE Steam Turbines:
This Section has 02 “GE Thermodyne France” Steam Turbines Rated power (2*24MW) Condensing Steam Turbines & 02 “GE Nevono pignino Italy” Steam Turbines One is Condensing Steam Turbine Rated power (60MW) for supply power to K-Electric & One is Back pressure Steam Turbine Rated Power (10MW) & 200 Ton/hr Steam Flow Supply to FFBL Process Plant.
CIRCULATING FLUDIZIED BED (CFB) BOILER:
This Section has 02 Coal Fired “Hyundai CFB Boiler Korea” Rated Capacity (Flow=2*250 Ton/hr, Pressure=92bar, Temperature=510c)
Coordination with Load Dispatch Center for Load Variations.
Coordination of other department in case of Maintenance jobs.
Switching of 132kv system for Breaker Operation.
Responds safety in an manner during process upset conditions specially in trip & blackout condition of the plant and responsible to ensuring actions are carried out in accordance with agreed black out Procedure.
Diagnose process problems brought in the notice of Shift engineer mention in log book and prepare detail work requests for rectification through Maximo work request system.
Monitor and operate safely (Gas turbine, Steam Turbine, HRSG, Pretreatment system, Demin plant) through Mark-Vie control HMI & Honey well DCS Operation.
Coordination with National power control center for Load Variations.
Coordination with OGDCL for fuel gas system.
Coordination of other department in case of Maintenance jobs.
Switching of 220kv system for Breaker Operation.
.
OPERATOR SKILL
Line up, isolation, normalization, priming, start-up, shutdown operation of the plant system.
Handled system issues from field area & Support to CCR Operator in Case of Trouble shooting Activities & Normal Plant Activities. .
Good command on flow and process diagrams of power plant system.
Working of critical conditions such as station blackout, power supply failure, and hazardous material leakage.
Addition of different types of chemicals by monitoring plant condition and water condition.
Reading of different API\'s
.