خلاصہ

Over 9 years of experience planning various projects, designing and developing LV, MV, and HV electrical systems and drawings, and executing pre-commissioning testing and maintenance in different sectors. Possess wide on-site engineering experience with deep knowledge of engineering principles and concepts along with strong expertise in control systems hardware, machine controls, and pneumatics. Adept at diagnosing malfunctioning systems, devices, and components to locate the cause of a breakdown and correct the problem. Accomplished communicator skilled in building and strengthening relationships across functions to drive cohesive, strategic operations with contractors and suppliers. Sound grasp of debugging systems and equipment.


My key skills include Operation & Maintenance, Electrical Design & Equipment, Material Management, Preventive Maintenance, Equipment Installation, Site Surveys & Support, Project Management, Organizational Skills, Operations Module Development, Strong Communication, Effective Team Player, Resolution Oriented, Process Improvement


Hands-on Experience: Extruder type Spinning Process Plant || Working on Controllers, like (Honeywell, Siemens etc.)


Different VFD’s (Siemens, Puma= P5, G7 || Calibrating of level, pressure & temp sensors.


Paperless Recorder (Yokogawa) || PI and IP Positioner/ Converter.


Reading Electrical, P&ID Diagram’s || Troubleshooting of Electrical Panel fault.


Troubleshooting Simatic S5, S7-200 and Fatek PLC || on Pneumatic Conveying System


My professional background and great industrial exposure coupled with an excellent track record makes me an ideal candidate for executive roles. As such I would welcome a discussion regarding opportunities with your organization that fit my background.

پراجیکٹس

ACT wind Energy

تجربہ

کمپنی کا لوگو
Manager Technical
ACT Group
جنوری ۲۰۲۰ - موجودہ | Thatta, Pakistan

Facilitate the design, construction, and commissioning of wind plant projects, liaised with power purchaser, and compliance of Energy purchase agreement, conducted monthly meetings with EPC contractors to carry out works for project construction.

Lead the work of subcontractors/consultants to ensure all plant activities execution in compliance with HSE regulation; ensure all compliance of O&M Contractual obligations.
Plan, lead, and execute plant maintenance work including equipment repairs, and inventory management; generate specific maintenance tenders, evaluate bids, shortlist contractors, and negotiate necessary contracts.
Spearheaded operations of two Wind plants including 2 substation and 40 wind turbines; reported projects to the higher management and stakeholders, lead site technical and administrative personnel and contractors working at site.
Render a keen eye for details to prepare plant reports including daily and monthly O&M and production reports, also maintain the plant\'s O&M and administrative procedures by implementing best practices.

کمپنی کا لوگو
Deputy Manager E&I
ACT Wind Pvt. Ltd (Formerly Tapal Wind Energy)
جنوری ۲۰۱۷ - دسمبر ۲۰۱۹ | Thatta, Pakistan

Spearheaded overall operation and maintenance of 132kV substation and wind turbine of GW 82/1500, documentation and detailed but effective reporting to higher management on daily status activities regarding plant operation and maintenance.

Led Engineers & technicians to handle maintenance of substation equipment like power transformers (31.5MVA), switch gears (132/33kV), protection relays, LV switch gears, Emergency diesel generator, communication system, RMUs and GSUs.
Monitored the substation SCADA Schneider PACiS IEC61850 with remote communication link IEC 101/104; instrumental in SLDs to guidance, implementation, and modifications for the Improvement of the system.
Troubleshooting & maintenance of Gold Wind Turbines (82/1500) E&I equipment, like (PLC, IGBTs, Cooling fans, VFDs, Motors, Yaw system, vibration, temperature, proximity sensors, anemometer and wind vane etc.
Designed and developed wind turbine electrical drawings; drove all efforts to monitor the Plan Shut down for maintenance of 132kV Grid station and Wind turbines.
Strategized and aligned all resources to arrange best isolations post-shut down and any fault rectification work, performed LOTO on each equipment under shutdown according to EHS procedure and best practice proposed.
Cross-checked and recorded the behavior of protection relays like Distance, over current, Differential and bus-bars protection (P543, P141, P632, P746), also provide technical support in setting and testing relays.

کمپنی کا لوگو
Project Engineer E&I
Tapal Wind Pvt. Ltd
اپریل ۲۰۱٦ - دسمبر ۲۰۱٦ | Thatta, Pakistan

Commissioning & Erection:

Supervised construction of project major phases including installation, erection, testing and per-commissioning of substation and wind turbines, coordinated with EPC Contractor, also supervised routine surveys/installation works.
Conducted detailed review of design-132/33KV Grid Station according to NTDCL specifications as well as IFC drawings and analyzed perfection of EPC contractor works as per IFC drawings.
Resolved design conflict within the multi-discipline Engineering team, executed work schedule, wrote reports, ensured project document accuracy, and reported to the Project Manager regarding allocation of resources on the project site.

Installation of E&I Equipment:

Installed Wind Turbines, Electrical & Instrumentation equipment, control & protection panels with protection relays of Schneider, MICOM, and SCADA as well as MV Switchgears, Converters, Telecom, Energy Meters Panels and Battery Banks.
Devised Lightning Protection, Power Transforms, Instrument Transformers, Surge Arrestors & 132KV Air Insulated Switchgear with detailed understanding of SLDs, Control and Interlocking diagrams.

کمپنی کا لوگو
Engineer E&I
Gatron Industries Ltd
جنوری ۲۰۱۳ - اپریل ۲۰۱٦ | Hub Chowki, Pakistan

Commissioning & Erection:

Troubleshoot and maintained all Electrical and instrument equipment installed in spinning process plant, reported the department HOD on daily status / activity, also attended meeting with department HOD related to plan issues/solutions.
Generated monthly troubleshooting and maintenance reports, worked on material management software (Customized), preparing of B.O.Q and work permits.
Led monitoring maintenance schedules, preventive & breakdown maintenance, major shutdowns & Commissioning work

تعلیم

NED University of Engineering & Technology
ماسٹرز, ماسٹر آف ایجوکیشن, Industrial Eleectronics‎
Industrial Electronics
CGPA 3.4/4
2014
Dawood University of Engineering & Technology (DCET)
بیچلرز, , Bachelors of Engineering‎
Controll Engineering, Instrumentation, Electronic Engineering
2011

پیشہ ورانہ مہارتیں

ماہر HMI DESINGING
ماہر Panel Designing
ماہر Technical Competence
متوسط Advance MS Excel
متوسط Agile Project Management
ماہر Architectural Skills
ابتدائی Budget Reconciliation
متوسط Business Intelligence Projects
متوسط Business Management Solutions
متوسط C Level Negotiation
متوسط Communication Skills
ماہر Computer Hardware and Software Command
ماہر Conservation Awareness
متوسط Contracts
ماہر Electric Power Management
متوسط Electrical Controls Designs
ماہر Electrical Diagnosis
ماہر Electrical Engineer
ماہر Electrical Troubleshooting
متوسط End to End Sales
ماہر Handling Assignments
متوسط MS Excel
متوسط Nutrition Management:
ماہر Operational Activities
ماہر Operational Tasks Handling
ماہر PLC Programming
ماہر PLC Programming skills
متوسط Power Electronics Designing
متوسط Pursuing News Stories
ماہر Record keeping
ماہر RESTful APIs
متوسط Tbricklaying
ماہر Urdu Fluency
متوسط عمليات الخدمات

زبانیں

ماہر اردو
متوسط انگریزی

آپ کن کمپنیز کی پیروی کر رہے ہیں